ABOUT US   |   NEWS   |   CONTACT US
You are here: Home » Products » Shr Laser Machine » CO2 laser » Medical laser equipment co2 fractional

loading

Share to:
sharethis sharing button

Medical laser equipment co2 fractional

  • Laser

  • CO2 Laser

  • Yes

  • Portable

  • CE

  • Guangdong, China

  • T&M

  • TM-126

  • Hair Removal, Anti-Puffiness, Face Lift, Pigment Removal, Skin Tightening, Whitening, Skin Rejuvenation, Tattoo Removal, Acne Treatment, Anti-Hair Removal, laser equipment co2 fractional, quarz laser tube/glass tube

  • laser equipment fractional

  • 110V/220V 50Hz/60Hz

  • 850W

  • wrinkle,hair,freckle,acne,scar removal

  • 10600nm

  • normal,fractional

  • <=0.1mm

  • 76*53*137cm+86*14*22cm

  • 16kg

Specifications

medical co2 fractioanl laser equipment
Quartz tube/glass tube
Acne/scar/freckle removal
ultra-pulse,continue,fractional

Welcome to Tingmay.

Please feel free to contact me via Skype:robertzhu77

or call me directly +86 13760769546

CO2 laser/CO2 Fractional Laser

1.skin resurfacing/acne removal/scar removal
2.photorejuvenation,acne treatment
3.fractional co2 laser
4.medical laser beauty equipment

Technical parameters:

Wavelength

10600nm

Laser type

Ultra-pulse, Continued, Fractional

Power

30w

Indication beam

635nm

Indication beam power

5mw

Spot diameter

0.1mm

Pulse delay

1ms-5000ms, 1ms/step

Pulse width

0.1ms-10ms, 1ms/step

Scanning times

1st-20th, 1st/step

Distance between spots

0.1mm-2.6mm. 1.1mm/step

Scanning patterning

straight line; square, rectangular, triangular, hexagonal, round, and oval.

Pattering size

diagonal length 0.1mm-20mm adjustable

Smoke exhaustion system

Built-in-air blow

Cooling system

Built-in circulating water cooling

Environmental temperature

5-40℃

Relative Humidity

80%

Power Supply

AC 220V±22V;50Hz±1Hz


Indications

Dermatology: the removal of excess material and hit moles, body odor
Gynecology: Cervical erosion
ENT: nasal polyps removed
Urology: Circumcision, genital warts
Anorectal: Hemorrhoids cutting

Physiotherapy: skin numbness, neck of inflammation, frozen shoulder, arthritis, the use of radiation beam expander

Complications and treatment measures

(1) Postoperative edema

Postoperative edema is divided into mild and moderate, and will dissipated in about a

week time. Ice bag can be used to reduce the postoperative edema.

(2) Erythema

Erythema is a normal reaction after taking Co2 treatment. The erythema occurrence is

proportional to the treatment dept, deeper treatment longer time erythema. The erythema

which is on the eyelid skin are particularly vulnerable to lasting longer time, because the

eyelid skin is thinner than normal skin.

(3) Ecchymosis

If ecchymosis appears in the epidermis, it may last for several weeks after treatment, but no

need to treat.

(4) Hypo-pigmented

Hypo-pigmented phenomenon shows up relatively late, most patients can feel apparently

usually. Some patients won’t feel until one year or more. The morbidity of depigmentation or

true depigmentation is not related with skin type, but depth of laser skin reconstruction

surgery.

(5) Pigmentation

The occurrence of pigmentation is associated with skin type, more common in Fitzpatrick Ⅲ

skin and higher type skin. The occurrence of this phenomenon has nothing to do with the use

of laser equipment.

(6) Infection

It is extremely rare. Local treatment part recently received radiation therapy or closed

dressing are prone to infection. Symptoms of infection are mainly pain, or associated with

burning and itching. Other symptoms include increased redness, yellow crusting or secretion,

wound erosion. For available preventive, you can use antibiotics or cloxacillin.

(7) Contact dermatitis

newborn thin epidermis is susceptible to various simulative effect of

external medication, so if not necessary, the use of external medication should be avoided

until the skin fully recover. We recommend that patients should avoid the use of cosmetics

and lotions, until two weeks after taking Co2 laser surgery.

(8) Itching

itching can be caused for a variety of reasons, including the wound is dry,

external lotions and stimulation of drugs. Another cause of itching may be infected. Itching

would be the signal of bacterial, fungal or viral infection. Pruritus after laser surgery

generally has good response to antihistamine drug, such as diphenhydramine(10mg or 25mg)

or cinnarizine (10mg). Cold compress can also improve the feeling of itching. External

corticosteroids also can relieve itching feeling.

(9) Acne and milia

Milia incidence may be correlated with the degree of heat damage of

tissue, thermal damage of tissue can cause skin damage of sebaceous glands, and it can

cause sebaceous gland duct to be blocked, then form abnormal. For treatment of acne and

milia, you can routinely take external use antibiotics, A Acid, α-hydroxy, and sebum

exclusion technique. Reasonable arrangement of life is useful for acne prevention and milia

recurrence after operating for patients with a history of having acne.

Laser acne removal/scar removal treatment pictures:

Laser gun accessories:

Operation screens:

Choose glass tubes/quarz rf tubes:

More pictures:

Previous: 
Next: 
If you would like to have a question then get in touch today, we are ready to assist 24/7.
We welcome your cooperation and we will develop with you.

 Factory-direct Connectivity Solutions.
 High quality, Competitive Price.
 Custom-tailored solutions.
 Problem-solving approach.

 
Guangzhou Tingmay beauty equipment CO., LTD is engaged in designing and manufacturing beauty equipment more than 10 years . 

INFORMATION

CATEGORIES

CONTACT US

 (+86)-13924166578 / (+86)-15018765608
 (+86)- 020-36517974
 tingmayg@tingmay.cc 
 Floor 7, No. 13, Erheng Road, Huanjiao Industrial Zone, Shijing Town, Baiyun District, Guangzhou, Guangdong, China (Mainland),